مقاله

Digital Distance Relaying

دانلود متن کاملرایگان، با حساب کاربری؛ ثبت نام با گوگل چند ثانیه است

چکیده(به انگلیسی؛ چکیده‌ی فارسی در دسترس نیست)

Increasing interest is being shown in the use of microprocessor for protection, switching and data acquisition required in modern high voltage substations. One of the most difficult functions to fulfill is that of transmission line distance protection employing samples of the voltage and current waveform taken from high voltage transducer equipment at the usual relaying point. This paper examines and compares different digital algorithms suitable for distance measurement, with particular reference to their accuracy and speed of calculation.

نویسندگان و وابستگی سازمانی
  1. A. M. Ranjbar — Electrical Engineering, Sharif University of Technology

اسناد مشابه

  • a novel algorithm for digital distance relaying

    مقالهروش های عددی در مهندسی (استقلال)فروزان قاسمی و رضا صفری, f.ghassemi and r.safari

    distance relays are used to protect ehv and hv transmission lines. over the past decades many algorithms have emerged for digital distance relays. these are based on the calculation of the transmission line impedance from the relaying to fault points. in this paper a novel method

  • Variable Digital Filter Response Time in a Digital Distance Relay

    سند علمی۱۹۹۶J. M. Kennedy, G. E. Alexander

    This paper will investigate the effect of digital filtering on the operating time of a generic digital distance relay. Two popular filtering approaches will be considered: the Cosine Filter and the Fourier Filter. The effects of several variables, such as sampling rate, fault loc

  • A New Digital Distance Relaying Based on the Fast Haar Transformation Using a Half Cycle Offset Free Signals

    مقاله‌ی دسترسی آزاد۱۹۹۴IEEJ Transactions on Power and EnergySang-HeeKang, Jong-KeunPark, Nam-HoKim

    A new high-speed digital distance relaying algorithm which uses fast Haar transformation techniques where transformation data window is a half cycle is proposed. In this proposed algorithm, to extract pure power frequency components, a newly designed dc-offset removing digital fi

  • Reach and Operating Time Correction of Digital Distance Relay

    مقاله‌ی دسترسی آزاد۲۰۱۷International Journal of Electrical and Computer Engineering (IJECE)A NSarwade, P KKatti, J GGhodekar

    Current and voltage signals recieved from conventional iron core Current Transformer (CT) and Voltage Transformer plays very important role for correct operation of Distance Distance Relay (DDR). Increase in secondary burden connected to CT causes it to saturate at earlier stage.

  • Proposed High-Performance Digital Distance Relay (Dept.E)

    مقاله‌ی دسترسی آزاد۲۰۲۰MEJ. Mansoura Engineering JournalA.Elmitwally

    This paper proposes a new design for high-performance digital distance relay. It is equipped with a dedicated decaying dc component estimation algorithm and a new method for compensation of ground fault resistance. The proposed relay algorithm can estimate and eliminate the dc de

  • Comparing Impact of STATCOM and SSSC on the Performance of Digital Distance Relay

    مقاله‌ی دسترسی آزاد۲۰۱۱Journal of Power ElectronicsAmirGhorbani

    In this paper the impact of a SSSC and a STATCOM on the impedance calculated by a distance relay is investigated. Both analytical analysis and simulations are provided. The STATCOM/SSSC control systems are modeled in detail. It is demonstrated that a SSSC has a greater impact on